Certification Manual
- 44 -
User Programming
o Time and Date = 9 + 4321
Downloader
o 8 + 4321 + 7 (0 any, 1 download, 2 upload)
o Must set account number
o Must set phone number
Buss devices & Sensors
Sensor Text = 081
Delete Sensors = 082
Press B to skip to next
A Learn sensors = 080
o Door/Window Sensor = group 25
o Pendant Sensor = group 28
o Learn sensors 8 + 4321 + 0 + 0 + 080
Partition #, Group #, Sensor #, Trip
Once these settings are changed, the control panel is ready to be
connected to the computer and have transmitters learned into it.
Other Programming Options
In addition to the settings that must be changed on the Concord
Panel out of the box, there are several programming features that should
be well understood by any installer and/or servicing technicians.
Zone Test: The zone test feature allows the installer to test the
signal strength of a given wireless transmitter (of any type).
o 8 + 4321 + 3
o The touchpad will read “Zone Test 5 Minutes”.
o If a call is placed and the signal strength is acceptable the
touchpad will read “Zone X OK
o If a call is placed and the signal strength is not acceptable
the touchpad will read Zone x Failed”, or the call will not
show up at all.