DAVISCOMMS (S) PTE LTD
TMR1P
(POCSAG
TM
TELEMETRY MESSAGING RECEIVER)
USER GUIDE AND
EVALUATION KIT MANUAL
1 500088R03
DAVISCOMMS (S) PTE LTD
Blk70 Ubi Crescent #01-07 Singapore 408570. Tel: (65) 65471127 Fax: (65) 65471129
Vista de página 0
1 2 3 4 5 6 ... 25 26

Resumo do Conteúdo

Página 1 - EVALUATION KIT MANUAL

DAVISCOMMS (S) PTE LTD TMR1P (POCSAGTM TELEMETRY MESSAGING RECEIVER) USER GUIDE AND EVALUATION KIT MANUAL

Página 2 - TABLE OF CONTENTS:

DAVISCOMMS (S) PTE LTD Sub-address: 4 Characters (0~9, a~z,, A~Z) This Sub-address can be enabled or disabled via the TPS. Prefix: “[[[

Página 3 - 1 TMR1P Product Features

DAVISCOMMS (S) PTE LTD the Windows TPS . For numeric message source, (‘0’ to ‘9’, ‘*’, ‘U’, ‘-‘, ‘[‘, or ‘]’) can be used as the trailer

Página 4

DAVISCOMMS (S) PTE LTD 3 TMR1P Examples Assuming the Sub-address is “1234”, Header1 is pre-programmed using the TPS as “00ff”, Trailer2 i

Página 5

DAVISCOMMS (S) PTE LTD iv) If the user sends out the following page: “1234 [[[[r]” Interpretation: This will Reset all the 8 ports to hig

Página 6

DAVISCOMMS (S) PTE LTD Please ensure you have the following: • TMR1P • Parallel cable (with DB25 connectors) • Programmer box (rectangula

Página 7

DAVISCOMMS (S) PTE LTD 5. TMR1P ELECTRICAL SPECIFICATION S/No Electrical Specifications Range Unit 01 Operating Frequency

Página 8

DAVISCOMMS (S) PTE LTD Operating for 900MHz +5 to +40 °C Storage -40 to +80 °C 10 Page Sensitivity 1200 Baud (TEM C.F = 22.5)

Página 9 - 2 TMR1P Message Protocol

DAVISCOMMS (S) PTE LTD 6. TMR EVALUATION KIT SET-UPS AND OPERATION The Evaluation board is designed to facilitate the testing and evaluat

Página 10 - DAVISCOMMS (S) PTE LTD

DAVISCOMMS (S) PTE LTD 12VDC power adapter D-sub 9-pin Serial cable(male) to connector onthe Evaluation Board Telemetry Message Receiver

Página 11

DAVISCOMMS (S) PTE LTD D-Sub 9-pin connector to SerialPort (COM ports) of PC DB25-pin connector to ParallelPort (LPT1) of PC Fig 2. Set-

Página 12 - 3 TMR1P Examples

DAVISCOMMS (S) PTE LTD TABLE OF CONTENTS: 1. TMR1P PRODUCT FEATURES... 3

Página 14

DAVISCOMMS (S) PTE LTD 6.3 Hardware Jumper Settings For TMR Evaluation Board ! Warning, If VIN2 (J4) is used to po

Página 15

D-Sub 9 pin Serial ConnectorRJ-45 Connector20 pin connectorPIN 3PIN 122500088R03TMR EVALUATION BOARD

Página 16

DAVISCOMMS (S) PTE LTD When you connect power (8V to 15V) to the VIN2 connection at J4, the jum

Página 17

TMR EVALUATION BOARD SCHEMATICS500088R0324

Página 18

DAVISCOMMS (S) PTE LTD 7. TMR1P 20-PIN CONNECTOR SPECIFICATION No. Description No. Description 1 SDATA 11 VIN3 2 D0 - 1

Página 19

DAVISCOMMS (S) PTE LTD 8. MODULE DIMENSIONS 26 500088R03 DAVISCOMMS (S) PTE LTD Blk70 Ubi Crescent #01-07 S

Página 20

DAVISCOMMS (S) PTE LTD 1 TMR1P Product Features 1.1 Product Description The TMR1P is able to receive alphanumeric messages and send v

Página 21

DAVISCOMMS (S) PTE LTD When a port control code sent is “0”, the corresponding port is set to low state or sink state. When a port contr

Página 22 - TMR EVALUATION BOARD

DAVISCOMMS (S) PTE LTD If Out Of Range (OOR) Indication is enabled in the TPS, the TMR1P can indicate an OOR condition. The LED on the de

Página 23

DAVISCOMMS (S) PTE LTD If flow control is enabled, the CTS line is used to determine if the host is ready to receive data from the TMR1P.

Página 24 - 500088R03

DAVISCOMMS (S) PTE LTD The TMR1P processes the received data only when the sub-address received is correct. The sub-address (4-characters:

Página 25

DAVISCOMMS (S) PTE LTD 1.19 Message Source ID Control The TMR1P can send any index number of the 7 capcode addresses at the start of

Página 26 - 26 500088R03

DAVISCOMMS (S) PTE LTD 2 TMR1P Message Protocol 2.1 Control Data Profile This is used to send control commands to the 8 output ports f